Signal Cable

<< | 1 | 2 | >>

  Lifeline┬« 2 Hour Rated CIC Cable

multiconductor FPL rated / 18, 16, 14 & 12 AWG / shielded and unshielded / 150 volt
  Ratings & Specifications

Meets 1999 National Fire Alarm Code (NFPA 72) requirements for survivability; UL Standard for Tests of Fire Resistive Cables, UL 2196; UL Listed FPL Fire Alarm Cable per UL Standard 1424; Electrical Circuit Protective System (FHIT) #24 of the UL Fire Resistance Directory; UL Listed NPLF Fire Alarm Cable per UL Standard 1425
         
  Line Wire

PE jacketed conductors / 10, 8 and 6 AWG
  Ratings & Specifications

AREMA Signal Manual Parts 10.3.10 and 10.3.21
         
  Reduced Diameter Control Cable with XLPE Insulation

multiple conductors / 18, 16, 14 & 12 AWG / LSZH, TP or XLPO jacket / 600 volt
  Raitings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-73-532 (NEMA WC 57); IEEE 383
         
  Reduced Diameter Instrumentation Cable (OS)

multiple XLPE insulated conductors / overall shield / 18 & 16 AWG / LSZH, TPO or XLPO jacket / 600 volt
  Raitings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-73-532 (NEMA WC 57); IEEE 383
         
Reduced Diameter Instrumentation Cable (POS)

multipair XLPE insulated conductors with overall shield / 18 & 16 AWG / LSZH, TPO or XLPO jacket / 600 volt
Raitings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-73-532 (NEMA WC 57); IEEE 383
         
Reduced Diameter Instrumentation Cable (PS)

shielded multipair XLPE insulated conductors / 18 & 16 AWG / LSZH, TPO or XLPO jacket / 600 volt
Ratings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-73-532 (NEMA WC 57); IEEE 383
         
Reduced Diameter Instrumentation Cable (PSOS)

dual shielded multipair XLPE insulated conductors / 18 & 16 AWG / LSZH, TPO or XLPO jacket / 600 volt
Ratings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-73-532 (NEMA WC 57); IEEE 383
         
  Reduced Diameter Power Cable (with grounds)

three XLPE insulated conductors with grounds / 12 AWG to 750 KCMIL / TPO or XLPO jacket / 600 volt
  Ratings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-95-658 (NEMA WC-70); IEEE 383
     
Reduced Diameter Power Cable (without grounds)

two or three XLPE insulated conductors without grounds / 12 AWG to 750 KCMIL / TPO or XLPO jacket / 600 volt
  Ratings & Specifications

UL Standard 44, 1277 and 1685; ICEA S-95-658 (NEMA WC-70); IEEE 383
     
Schedule 40 LSZH Duct

flame-retardant duct / 1, 1.25, 1.5, 2, 2.5 & 3 inches inner diameter
  Ratings & Specifications

GR-356-CORE for Fiber Optic Duct; ASTM D-2447 Schedule 40 dimensions; ASTM D-6070 for physical properties; UL-1581 Vertical Tray Flame Test
     
Track Wire

single or duplex EPR insulated conductors / 9, 8 & 6 AWG / PE jacket / 600 and 2000 volt
  Ratings & Specifications

AREMA Signal Parts 10.3.16, 10.3.19 and 10.3.21; ICEA S-95-658 (NEMA WC 70)
     
Underground Armored Railroad Signal Cable

with multiple EPR insulated conductors / 14, 12, 10, 9 & 6 AWG / PE jacket / 600 volt
  Ratings & Specifications

AREMA Signal Parts 10.3.17, 10.3.19, 10.3.21; ICEA S-95-658 (NEMA WC70)
     
Underground Signal Cable

multiple EPR insulated conductors / 14, 10, 9 & 6 AWG / PE jacket / 600 and 2000 volt
  Ratings & Specifications